Sun Microsystems Sun StorEdge 3510 FC Array 3510 Instrukcja Użytkownika Strona 22

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 30
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 21
18 Sun StorEdge 3000 Family Best Practices Manual October 2003
2. Connect expansion units if needed.
3. Configure cache optimization.
4. Ensure fibre connection is set to loop mode.
5. Configure target IDs.
6. Create one Logical Drive for each server and configure spare disks.
7. Map Logical Drive 0 to channels 0 and 5 of the primary controller.
8. Map Logical Drive 1 (if created) to channels 1 and 4 of the secondary controller.
9. Map Logical Drive 2 to channels 0 and 5 of the primary controller
10. Map Logical Drive 3 (if created) to channels 1 and 4 of the secondary controller.
11. Connect the first server to port 0 of the upper controller and port 5 of the lower
controller.
12. Connect the second server (if needed) to port 1 of the lower controller and port 4
of the upper controller.
13. Connect the third server (if needed) to port 0 of the lower controller and port 5 of
the upper controller.
14. Connect the fourth server (if needed) to port 1 of the upper controller and port 4 of
the lower controller.
15. Install and enable multipathing software on each connected server.
Przeglądanie stron 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Komentarze do niniejszej Instrukcji

Brak uwag