14 Sun StorEdge 3000 Family Best Practices Manual October 2003
Non-Redundant DAS Setup Details
FIGURE 5 Non-Redundant DAS Connections
The general procedure for creating this configuration follows.
1. Check the position of installed SFP modules. Move or add SFP modules as
necessary to support the connections needed.
2. Connect expansion units if needed.
3. Configure cache optimization
4. Create one Logical Drive for each server and configure spare disks.
TABLE 2 Setup Summary for Non-Redundant DAS
Channel Number Primary ID Number
Secondary ID
Number
0 40 N/A
1 43 N/A
2 14 N/A
3 14 N/A
4 44 N/A
5 47 N/A
Server 1 Server 3 Server 4 Server 2