Sun-microsystems 6900 Instrukcja Użytkownika Strona 169

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 168
Chapter 11 Example of Fault Isolation 149
Sun Proprietary/Confidential: Internal Use Only
The primary path to Drive F: failed. The alternate path is currently handling all
of the I/O.
3. Check the HBA
Using the HBA utility (Qlogic SANblade in this example), confirm the fault.
FIGURE 11-3 Fault Confirmation Using QLogic SunBlade
4. Isolate the components in the path.
The components in the path are the HBA, the cable, the switch-side GBIC, and the
Sun StorEdge network FC switch itself.
To isolate all components, use a combination of the Storage Automated Diagnostic
Environment and the HBA utility (QLogic SunBlade).
Note If no HBA utility is present, or if the utilities do not offer diagnostics, a best
guess effort will have to suffice. Storage Automated Diagnostic Environment cannot
test HBAs on Microsoft Windows 2000 hosts at this time.
Przeglądanie stron 168
1 2 ... 164 165 166 167 168 169 170 171 172 173 174 ... 203 204

Komentarze do niniejszej Instrukcji

Brak uwag