Sun Fire
X2250 Server
Service Manual
Part No. 820-4593-12, Rev. A
February 2010
Przeglądanie stron 0
1 2 3 4 5 6 ... 133 134

Podsumowanie treści

Strona 1 - Service Manual

Sun Microsystems, Inc.www.sun.comSubmit comments about this document by clicking the Feedback[+] link at: http://docs.sun.comSun Fire™X2250 ServerServ

Strona 2

x Sun Fire X2250 Server Service Manual • April 2009Typographic ConventionsRelated DocumentationTo view a list of documents that are available for the

Strona 3 - Contents

A-2 Sun Fire X2250 Server Service Manual • April 2009A.2 Power SpecificationsMaximum continuous power is 500 W. Other specifications are shown in thef

Strona 4

Appendix A System Specifications A-3A.3 Environmental SpecificationsEnvironmental specifications for the Sun Fire X2250 server are shown in TABLE A-6.

Strona 5 - Contents v

A-4 Sun Fire X2250 Server Service Manual • April 2009A.4 Serial Connector Pin AssignmentsThe serial management port connector is an RS-232-F RJ-45 typ

Strona 6

B-1APPENDIXBUsing the Tools & Drivers CDThis chapter contains information about the Sun Fire X2250 Server Tools & DriverCD. It contains inform

Strona 7 - Contents vii

B-2 Sun Fire X2250 Server Service Manual • April 2009B.2 Updating BIOSYou can update the BIOS from the Tools & Drivers CD using the local X2250 se

Strona 8 - Index Index–1

Appendix B Using the Tools & Drivers CD B-3B.2.2 Updating Sun Fire X2250 BIOS From a RemoteClientThe following requirement must be met prior to up

Strona 9 - How This Book Is Organized

B-4 Sun Fire X2250 Server Service Manual • April 2009B.3 Updating SP FirmwareYou can update the SP firmware from the Tools & Drivers CD using one

Strona 10 - Typographic Conventions

Appendix B Using the Tools & Drivers CD B-53. Ensure that the OS on the platform is shut down.4. Log in to the Sun Fire X2250 ILOM CLI with Admini

Strona 11 - Third-Party Web Sites

B-6 Sun Fire X2250 Server Service Manual • April 20095. Select Maintenance --> Firmware Upgrade tabs.The Firmware Upgrade page appears.6. Click Ent

Strona 12 - Sun Welcomes Your Comments

Appendix B Using the Tools & Drivers CD B-7B.4 Booting the Tools & Drivers CD From aPXE ServerIf you have a Sun Fire X2250 server that does no

Strona 13

Preface xiSupport and TrainingProduct UpdatesFor product updates that you can download for the Sun Fire X2250 server, pleasevisit the following web si

Strona 14 - 1.1 Features

B-8 Sun Fire X2250 Server Service Manual • April 2009The default directory for the PXE image is usually /tftpboot/linux-install.The remainder of this

Strona 15 - 1.2.1 Preinstalled Software

Appendix B Using the Tools & Drivers CD B-99. Edit the Boot Message Screen as follows.a. Open the boot.msg file in a text editor.b. Type the follo

Strona 16 - 1.3 Hardware System Overview

B-10 Sun Fire X2250 Server Service Manual • April 2009B.4.2 Accessing the Tools & Drivers CD From the TargetSun Fire X2250 ServerYou will need the

Strona 17 - 1.3.2 Internal Components

Appendix B Using the Tools & Drivers CD B-11B.5 Intel PROSET Driver SoftwareIncluded on the Tools & Drivers CD is a driver software package fo

Strona 18

B-12 Sun Fire X2250 Server Service Manual • April 20092. Locate the Product Part Number (PPN) from the CIS sheet (or from either ILOMor sdfru -l befor

Strona 19 - Processor Configuration

C-1APPENDIXCInstalling the Server Into a RackWith Optional Slide RailsPerform the procedures in this chapter to install your server into a four-post r

Strona 20 - FIGURE 1-1

C-2 Sun Fire X2250 Server Service Manual • April 2009C.1 Disassembling the Slide Rails BeforeInstallationUse this procedure to remove the mounting bra

Strona 21 - 1.4.4 Clearing the CMOS

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-3C.2 Installing the Mounting Brackets Ontothe ServerUse this procedure to ins

Strona 22

C-4 Sun Fire X2250 Server Service Manual • April 20094. Repeat Steps 1 through 3 to install the remaining mounting bracket on the otherside of the ser

Strona 23 - Troubleshooting

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-5FIGURE C-3 Slide-Rail Assembly Mounting to Rack Post3. Repeat Step 1 and Ste

Strona 24 - 2.1 Troubleshooting Overview

xii Sun Fire X2250 Server Service Manual • April 2009WarrantyFor specific details regarding your warranty, visit:http://www.sun.com/service/support/wa

Strona 25 - Chapter 2 Troubleshooting 2-3

C-6 Sun Fire X2250 Server Service Manual • April 2009FIGURE C-4 Setting the Rail Width5. Tighten the screws on the brackets.6. Remove the spacer and c

Strona 26 - Troubleshooting Procedures

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-78. If available, extend the anti-tilt bar at the bottom of the rack. (See FI

Strona 27 - Chapter 2 Troubleshooting 2-5

C-8 Sun Fire X2250 Server Service Manual • April 20091. Push the slide rails into the slide-rail assemblies in the rack as far as possible.2. Raise th

Strona 28 - Problem Possible solution

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-9Caution – Verify that the server is securely mounted in the rack and that th

Strona 29 - Chapter 2 Troubleshooting 2-7

C-10 Sun Fire X2250 Server Service Manual • April 2009FIGURE C-7 Inserting the CMA Rail Extension Into the Back of the Left Slide RailCMA railextensio

Strona 30

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-114. Verify that the CMA rail extension engages the slide rail, as shown inFI

Strona 31 - Performing Diagnostics

C-12 Sun Fire X2250 Server Service Manual • April 20095. Insert the CMA’s mounting bracket connector into the right slide rail until theconnector lock

Strona 32

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-136. Insert the right CMA slide-rail connector into the right slide-rail asse

Strona 33 - Option Description

C-14 Sun Fire X2250 Server Service Manual • April 20097. Insert the left CMA slide-rail connector into the rail extension on the left slide-rail assem

Strona 34 - Diagnostics Tests menu

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-158. Position the cable hangers in the appropriate mounting holes in the CMA

Strona 35

1-1CHAPTER1Sun Fire X2250 Server OverviewThis chapter provides an overview of the Sun Fire X2250 server, as well as power-onand power-off procedures a

Strona 36 - 3.3.1 Testing the Hard Disk

C-16 Sun Fire X2250 Server Service Manual • April 2009C.6 Verifying Operation of the Slide Railsand CMAUse this procedure to ensure that the slide rai

Strona 37 - 3.4 Immediate Burn-in Testing

Index-1IndexAair ductlocation, 1-6, 4-5replacing, 4-20altitude specifications, A-3Bbatterylocation, 1-6, 4-5replacing, 4-33BIOS firmwareCD, 1-4updating

Strona 38

Index-2 Sun Fire X2250 Server Service Manual • February 2010diagnostics CD, 1-4DIMMs, see memory modulesdriver updates, -xidual blower modulereplacing

Strona 39 - 3.5 Deferred Burn-in Testing

Index-3physical specifications, A-1postinstallation instructions, 4-3Power button, 1-5power connector, 1-5power LED, 1-5power problemstroubleshooting,

Strona 40

Index-4 Sun Fire X2250 Server Service Manual • February 2010Tools and Drivers CDdescription, 1-4tools for maintenance procedures, 4-1troubleshooting,

Strona 41

1-2 Sun Fire X2250 Server Service Manual • April 20091.1 FeaturesTABLE 1-1 lists the system’s key components.1.2 Operating System and SoftwareThis sec

Strona 42 - ■ Select Yes and press Enter

Chapter 1 Sun Fire X2250 Server Overview 1-31.2.1 Preinstalled SoftwareIf you ordered a hard drive with your Sun Fire X2250 server, the hard drive mig

Strona 43

1-4 Sun Fire X2250 Server Service Manual • April 20091.2.3 Tools & Drivers CD SoftwareThe Sun Fire X2250 server Tools & Drivers CD, which is a

Strona 44

Chapter 1 Sun Fire X2250 Server Overview 1-5FIGURE 1-2 shows the back panel of the Sun Fire X2250 server.FIGURE 1-2 Back Panel1.3.2 Internal Component

Strona 45 - Solaris 10 Operating System

1-6 Sun Fire X2250 Server Service Manual • April 2009FIGURE 1-3 Sun Fire X2250 Server System ComponentsTABLE 1-4 Sun Fire X2250 Server Internal Compon

Strona 46 - 3.7 Show Results Summary

Chapter 1 Sun Fire X2250 Server Overview 1-71.4 Powering On and Powering Off theServerYou only need to apply standby power to the server at this point

Strona 47

PleaseRecycleCopyright © 2010 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.Sun Microsystems,

Strona 48 - 3.10 Exit to DOS

1-8 Sun Fire X2250 Server Service Manual • April 20091.4.2 Powering On Main Power ModeTo power on main power for all server components:1. Verify that

Strona 49 - 4.1 Tools and Supplies Needed

Chapter 1 Sun Fire X2250 Server Overview 1-91.4.4 Clearing the CMOSYou can use this procedure to clear the server's CMOS settings in the case of

Strona 50 - 4.2 Installation Precautions

1-10 Sun Fire X2250 Server Service Manual • April 2009

Strona 51 - FIGURE 1-2)

2-1CHAPTER2TroubleshootingThis chapter contains information on troubleshooting procedures and technicalsupport contacts.The following sections are inc

Strona 52 - Removing the Server Cover

2-2 Sun Fire X2250 Server Service Manual • April 20092.1 Troubleshooting OverviewBefore troubleshooting your specific server problem, answer the follo

Strona 53 - 5 DIMM slots (4) 13 I/O board

Chapter 2 Troubleshooting 2-32.2.1 Performing an External Visual Inspection1. Turn off the system and any attached peripherals (if applicable).2. Veri

Strona 54

2-4 Sun Fire X2250 Server Service Manual • April 20092.3 Troubleshooting ProceduresTABLE 2-1 lists problems that might arise as you use your server. P

Strona 55 - 4.5.1 Replacing the I/O Board

Chapter 2 Troubleshooting 2-5System cannot readthe hard diskinformation.Do the following:1. Turn off the server by pressing the Power button.2. Remove

Strona 56 - Installing the I/O Board

2-6 Sun Fire X2250 Server Service Manual • April 2009No video is displayedon the monitorscreen.Check the following:• Is the monitor cable connected to

Strona 57 - 35W cards

Chapter 2 Troubleshooting 2-72.4 Getting Technical AssistanceIf the troubleshooting procedures in this chapter fail to solve your problem, seeTABLE 2-

Strona 58 - FIGURE 4-7

iiiContentsPreface ix1. Sun Fire X2250 Server Overview 1–11.1 Features 1–21.2 Operating System and Software 1–21.2.1 Preinstalled Software 1–31.2.2 Su

Strona 59 - Removing a PCIe Card

2-8 Sun Fire X2250 Server Service Manual • April 2009

Strona 60 - Installing the PCIe Card

3-1CHAPTER3Performing DiagnosticsThis chapter assists you with using the Diagnostics application on the Sun Fire X2250Server Tools & Drivers CD. T

Strona 61 - Removing a Hard Disk Drive

3-2 Sun Fire X2250 Server Service Manual • April 20093.1 Pc-Check Diagnostics OverviewSun Fire X2250 server diagnostics are contained in the DOS-based

Strona 62 - Installing a Hard Disk Drive

Chapter 3 Performing Diagnostics 3-3To run a specific hardware component test, select Advanced Diagnostics Test.Torunone of the test scripts supplied

Strona 63

3-4 Sun Fire X2250 Server Service Manual • April 20093.3 Advanced Diagnostics Tests MenuOptionsTABLE 3-2 gives the name and a brief description of eac

Strona 64

Chapter 3 Performing Diagnostics 3-5Diskettes Not applicable for the Sun Fire X2250 server.Hard Disks Details information about the hard disk, and inc

Strona 65 - Carrier” on page 4-14

3-6 Sun Fire X2250 Server Service Manual • April 20093.3.1 Testing the Hard Disk1. From the main menu, choose Advanced Diagnostics Tests.2. From the A

Strona 66

Chapter 3 Performing Diagnostics 3-7 Device Test SettingsEnables you to select the test time durations of the devices and the test level. Number of

Strona 67 - Removing the ODD Filler Panel

3-8 Sun Fire X2250 Server Service Manual • April 2009When you select the Immediate Burn-in Testing menu option, the ContinuousBurn-in Testing window i

Strona 68 - 4.5.6 Replacing the Air Duct

Chapter 3 Performing Diagnostics 3-91. From the main menu, choose Immediate Burn-in Testing.The top portion of the window lists the options described

Strona 69 - , aligning the baffle

iv Sun Fire X2250 Server Service Manual • February 20102.1 Troubleshooting Overview 2–22.2 Performing Visual Inspections 2–22.2.1 Performing an Extern

Strona 70 - Installing the Air Duct

3-10 Sun Fire X2250 Server Service Manual • April 20092. Complete one of the following options: Load Burn-in ScriptEnter one of the following: quick

Strona 71 - Removing the Power Supply

Chapter 3 Performing Diagnostics 3-11 Section 3.6.3, “Creating a Log File on the Diagnostic Partition” on page 3-12 Section 3.6.4, “Accessing the Di

Strona 72 - Installing the Power Supply

3-12 Sun Fire X2250 Server Service Manual • April 20099. Type Y to erase the data and the partition.10. Repeat Step 6 through Step 9 until all partiti

Strona 73 - Removing the Fan Module

Chapter 3 Performing Diagnostics 3-13The following procedure shows an example of how to create and access a log file onthe diagnostic partition for th

Strona 74 - Installing the Fan Module

3-14 Sun Fire X2250 Server Service Manual • April 20094. Determine if your diagnostic partition has been configured to be mounted bytyping the followi

Strona 75

Chapter 3 Performing Diagnostics 3-153.6.5 Accessing the Diagnostic Partition on theSolaris 10 Operating SystemTo access the diagnostic partition on t

Strona 76

3-16 Sun Fire X2250 Server Service Manual • April 20093.6.6 Accessing the Diagnostic Partition on theWindows Server 2003 Operating SystemThe Windows 2

Strona 77 - 4.5.10.2 Removing a DIMM

Chapter 3 Performing Diagnostics 3-17 MotherboardThis section shows the following tests conducted against the motherboard:DMA Controller Tests, Syste

Strona 78 - Bank 1 DIMM Slot Locations

3-18 Sun Fire X2250 Server Service Manual • April 20093.8 Print Results ReportThe Print Results Report option enables you to print system diagnostic r

Strona 79 - 4.5.10.3 Installing a DIMM

4-1CHAPTER4Maintaining the Sun Fire X2250ServerThis chapter describes how to add, replace, and configure components in the SunFire X2250 server after

Strona 80 - Installing a DIMM

Contents v3.10 Exit to DOS 3–184. Maintaining the Sun Fire X2250 Server 4–14.1 Tools and Supplies Needed 4–14.2 Installation Precautions 4–24.2.1 ESD

Strona 81 - FIGURE 4-30 for the

4-2 Sun Fire X2250 Server Service Manual • April 2009 Alcohol pads (for CPU replacement by service personnel only) 5 mm nut driver (for motherboard

Strona 82 - Removing the System Battery

Chapter 4 Maintaining the Sun Fire X2250 Server 4-32. Remove the server cover.See Section 4.3, “Powering Off the Server and Removing the Cover” on pag

Strona 83 - Installing the System Battery

4-4 Sun Fire X2250 Server Service Manual • April 20094. Label and disconnect all peripheral cables and all telecommunication linesconnected to I/O con

Strona 84 - FIGURE 4-32)

Chapter 4 Maintaining the Sun Fire X2250 Server 4-54.4 Locations of Server ComponentsFIGURE 4-2 Sun Fire X2250 Server System ComponentsTABLE 4-1 Sun F

Strona 85 - Removing a Heatsink

4-6 Sun Fire X2250 Server Service Manual • April 20094.5 Component Replacement ProceduresThe following components are customer-replaceable units (CRUs

Strona 86 - Removing the CPU

Chapter 4 Maintaining the Sun Fire X2250 Server 4-74.5.1 Replacing the I/O BoardThe following procedures describe how to remove and replace an I/O boa

Strona 87 - Installing the CPU

4-8 Sun Fire X2250 Server Service Manual • April 20094.5.1.2 Installing the I/O BoardTo install the I/O board:1. Position the I/O board on top of the

Strona 88 - FIGURE 4-35

Chapter 4 Maintaining the Sun Fire X2250 Server 4-94.5.2 Replacing the PCIe Card and Riser AssemblyNote – Many of the illustrations in this section sh

Strona 89 - 4.5.13 Installing a New CPU

4-10 Sun Fire X2250 Server Service Manual • April 2009Note – The examples shown in these procedures use the x8 card, but the installationand removal i

Strona 90

Chapter 4 Maintaining the Sun Fire X2250 Server 4-11FIGURE 4-7 Removing a PCIe Card4.5.2.2 Installing the PCIe Card and Riser Card AssemblyTo install

Strona 91 - Installing the Heatsink

vi Sun Fire X2250 Server Service Manual • February 20104.5.7 Replacing the Power Supply 4–224.5.7.1 Removing the Power Supply 4–224.5.7.2 Installing t

Strona 92 - 4.5.14 Replacing Cables

4-12 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-9 Installing the PCIe Card3. Reinstall the riser assembly into the connector on the mot

Strona 93 - 4.5.15 Motherboard

Chapter 4 Maintaining the Sun Fire X2250 Server 4-134. Check the routing of all cables for obstructions, and then reinstall the cover asdescribed in S

Strona 94 - Removing the Motherboard

4-14 Sun Fire X2250 Server Service Manual • April 20093. Grasp the carrier bezel with both hands and carefully pull the carrier out of thedrive bay.No

Strona 95 - Installing the Motherboard

Chapter 4 Maintaining the Sun Fire X2250 Server 4-154.5.4 Replacing an HDD Backplane AssemblyThe following procedure describes how to replace the hard

Strona 96 - 7. Replace the system cover

4-16 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-13 Removing the HDD Backplane Assembly4.5.4.2 Replacing an HDD BackplaneTo install the

Strona 97

Chapter 4 Maintaining the Sun Fire X2250 Server 4-17FIGURE 4-14 Replacing the HDD Backplane Assembly5. Reinsert the HDD as described in Section 4.5.3.

Strona 98

4-18 Sun Fire X2250 Server Service Manual • April 20094.5.5 Removing and Installing the ODD DriveAssemblyThe following procedure describes how to repl

Strona 99 - System Specifications

Chapter 4 Maintaining the Sun Fire X2250 Server 4-194. Pull the ODD drive out the front of the chassis.Caution – Move the assembly by grasping it by i

Strona 100 - A.2 Power Specifications

4-20 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-17 Installing the ODD Assembly4. Reinstall the ODD drive cable.5. Check the routing of

Strona 101 - TABLE A-6

Chapter 4 Maintaining the Sun Fire X2250 Server 4-21FIGURE 4-18 Removing the Air Duct4.5.6.2 Installing the Air DuctTo install the air duct:1. Positio

Strona 102

Contents viiA.4 Serial Connector Pin Assignments A–4B. Using the Tools & Drivers CD B–1B.1 Tools & Drivers CD Contents B–1B.2 Updating BIOS B–

Strona 103

4-22 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-19 Installing the Air Duct4.5.7 Replacing the Power SupplyThe following procedures desc

Strona 104 - B.2 Updating BIOS

Chapter 4 Maintaining the Sun Fire X2250 Server 4-23FIGURE 4-20 Removing the Power Supply6. Lift the power supply out of the chassis.4.5.7.2 Installin

Strona 105

4-24 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-21 Installing the Power Supply4. Connect three of the power supply cables to the mother

Strona 106 - B.3 Updating SP Firmware

Chapter 4 Maintaining the Sun Fire X2250 Server 4-257. Replace the air duct. See Section 4.5.6.2, “Installing the Air Duct” on page 4-21.8. Check the

Strona 107 - B.3.2 ILOM Web Interface

4-26 Sun Fire X2250 Server Service Manual • April 20094.5.8.2 Installing the Fan ModuleTo install the system fan module:1. Position the fan so that th

Strona 108

Chapter 4 Maintaining the Sun Fire X2250 Server 4-271. Power off the system and remove the cover as described in Section 4.3,“Powering Off the Server

Strona 109 - PXE Server

4-28 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-25 Installing the Dual Blower Module2. Gently push the blower module down, until you he

Strona 110 - # cd /syslinux-3.09/memdisk

Chapter 4 Maintaining the Sun Fire X2250 Server 4-29 DIMM pairs must be populated in the following DIMM slot order: A0 & B0, C0 &D0, A1 &

Strona 111

4-30 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-27 Bank 1 DIMM Slot Locations3. Remove a DIMM by pressing down on the ejector levers at

Strona 112 - Sun Fire X2250 Server

Chapter 4 Maintaining the Sun Fire X2250 Server 4-31FIGURE 4-28 Removing a DIMM4.5.10.3 Installing a DIMMTo install a DIMM:1. Refer to Section 4.5.10.

Strona 113 - Mainboard is Replaced

viii Sun Fire X2250 Server Service Manual • February 2010Index Index–1

Strona 114

4-32 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-29 Installing a DIMM4. Using both thumbs, press the DIMM straight down into the DIMM sl

Strona 115 - With Optional Slide Rails

Chapter 4 Maintaining the Sun Fire X2250 Server 4-334.5.11 Replacing the System BatteryThe system battery is a common CR2032 calculator battery.You mi

Strona 116 - Installation

4-34 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-30 Removing the System BatteryCaution – Do not dispose of the battery with regular wast

Strona 117 - FIGURE C-2.)

Chapter 4 Maintaining the Sun Fire X2250 Server 4-354.5.11.2 Installing the System BatteryTo install the system battery:1. Insert the new system batte

Strona 118 - FIGURE C-3.)

4-36 Sun Fire X2250 Server Service Manual • April 20094.5.12 Replacing a CPU and HeatsinkThe following procedure describes how to replace a CPU. The S

Strona 119 - FIGURE C-4.)

Chapter 4 Maintaining the Sun Fire X2250 Server 4-37FIGURE 4-32 Removing a HeatsinkCaution – The heatsink can become extremely hot. Be sure it has had

Strona 120 - Rail-width spacer

4-38 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-33 Removing the CPU8. Lift the CPU out of the socket, leaving the release lever in the

Strona 121 - Assemblies

Chapter 4 Maintaining the Sun Fire X2250 Server 4-393. Align the small triangle, on the upper left corner of the CPU, with the triangleon the corner o

Strona 122 - FIGURE C-6.) Continue

4-40 Sun Fire X2250 Server Service Manual • April 20097. Use the entire syringe contents to apply thermal grease in a circular pattern tothe top of th

Strona 123 - Assembly

Chapter 4 Maintaining the Sun Fire X2250 Server 4-41FIGURE 4-35 Installing the Heatsink13. Reinstall the cover.4.5.13 Installing a New CPUNote – Repla

Strona 124 - Left slide-rail

ixPrefaceThe Sun Fire X2250 Server Service Manual provides a detailed description of thehardware and software applications that support the Sun Fire™

Strona 125 - Left slide rail

4-42 Sun Fire X2250 Server Service Manual • April 20093. Ensure that the socket release lever is in the fully open, perpendicular positionand the CPU

Strona 126 - CMA mounting

Chapter 4 Maintaining the Sun Fire X2250 Server 4-437. Rotate the socket release lever down until it snaps into place, securing the CPUin the socket.8

Strona 127 - Right slide

4-44 Sun Fire X2250 Server Service Manual • April 20094.5.14 Replacing CablesFIGURE 4-38 shows the routing of the cables and motherboard connector loc

Strona 128 - (on left slide rail)

Chapter 4 Maintaining the Sun Fire X2250 Server 4-45TABLE 4-3 describes the motherboard cable connections.4.5.15 MotherboardThe following procedures d

Strona 129 - CMA cable hanger

4-46 Sun Fire X2250 Server Service Manual • April 20096. Using a 5-mm nut driver, remove the screws attaching the serial connector to thechassis.FIGUR

Strona 130

Chapter 4 Maintaining the Sun Fire X2250 Server 4-471. Center the motherboard on the chassis so that the screw holes in themotherboard align with the

Strona 131

4-48 Sun Fire X2250 Server Service Manual • April 20096. Reconnect all internal system cables.See Section 4.5.14, “Replacing Cables” on page 4-45.7. R

Strona 132

Chapter 4 Maintaining the Sun Fire X2250 Server 4-49

Strona 133

4-50 Sun Fire X2250 Server Service Manual • April 2009

Strona 134

A-1APPENDIXASystem SpecificationsThis Appendix contains the following specifications for the Sun Fire X2250 server. Section A.1, “Physical Specificat