Sun Microsystems, Inc.www.sun.comSubmit comments about this document by clicking the Feedback[+] link at: http://docs.sun.comSun Fire™X2250 ServerServ
x Sun Fire X2250 Server Service Manual • April 2009Typographic ConventionsRelated DocumentationTo view a list of documents that are available for the
A-2 Sun Fire X2250 Server Service Manual • April 2009A.2 Power SpecificationsMaximum continuous power is 500 W. Other specifications are shown in thef
Appendix A System Specifications A-3A.3 Environmental SpecificationsEnvironmental specifications for the Sun Fire X2250 server are shown in TABLE A-6.
A-4 Sun Fire X2250 Server Service Manual • April 2009A.4 Serial Connector Pin AssignmentsThe serial management port connector is an RS-232-F RJ-45 typ
B-1APPENDIXBUsing the Tools & Drivers CDThis chapter contains information about the Sun Fire X2250 Server Tools & DriverCD. It contains inform
B-2 Sun Fire X2250 Server Service Manual • April 2009B.2 Updating BIOSYou can update the BIOS from the Tools & Drivers CD using the local X2250 se
Appendix B Using the Tools & Drivers CD B-3B.2.2 Updating Sun Fire X2250 BIOS From a RemoteClientThe following requirement must be met prior to up
B-4 Sun Fire X2250 Server Service Manual • April 2009B.3 Updating SP FirmwareYou can update the SP firmware from the Tools & Drivers CD using one
Appendix B Using the Tools & Drivers CD B-53. Ensure that the OS on the platform is shut down.4. Log in to the Sun Fire X2250 ILOM CLI with Admini
B-6 Sun Fire X2250 Server Service Manual • April 20095. Select Maintenance --> Firmware Upgrade tabs.The Firmware Upgrade page appears.6. Click Ent
Appendix B Using the Tools & Drivers CD B-7B.4 Booting the Tools & Drivers CD From aPXE ServerIf you have a Sun Fire X2250 server that does no
Preface xiSupport and TrainingProduct UpdatesFor product updates that you can download for the Sun Fire X2250 server, pleasevisit the following web si
B-8 Sun Fire X2250 Server Service Manual • April 2009The default directory for the PXE image is usually /tftpboot/linux-install.The remainder of this
Appendix B Using the Tools & Drivers CD B-99. Edit the Boot Message Screen as follows.a. Open the boot.msg file in a text editor.b. Type the follo
B-10 Sun Fire X2250 Server Service Manual • April 2009B.4.2 Accessing the Tools & Drivers CD From the TargetSun Fire X2250 ServerYou will need the
Appendix B Using the Tools & Drivers CD B-11B.5 Intel PROSET Driver SoftwareIncluded on the Tools & Drivers CD is a driver software package fo
B-12 Sun Fire X2250 Server Service Manual • April 20092. Locate the Product Part Number (PPN) from the CIS sheet (or from either ILOMor sdfru -l befor
C-1APPENDIXCInstalling the Server Into a RackWith Optional Slide RailsPerform the procedures in this chapter to install your server into a four-post r
C-2 Sun Fire X2250 Server Service Manual • April 2009C.1 Disassembling the Slide Rails BeforeInstallationUse this procedure to remove the mounting bra
Appendix C Installing the Server Into a Rack With Optional Slide Rails C-3C.2 Installing the Mounting Brackets Ontothe ServerUse this procedure to ins
C-4 Sun Fire X2250 Server Service Manual • April 20094. Repeat Steps 1 through 3 to install the remaining mounting bracket on the otherside of the ser
Appendix C Installing the Server Into a Rack With Optional Slide Rails C-5FIGURE C-3 Slide-Rail Assembly Mounting to Rack Post3. Repeat Step 1 and Ste
xii Sun Fire X2250 Server Service Manual • April 2009WarrantyFor specific details regarding your warranty, visit:http://www.sun.com/service/support/wa
C-6 Sun Fire X2250 Server Service Manual • April 2009FIGURE C-4 Setting the Rail Width5. Tighten the screws on the brackets.6. Remove the spacer and c
Appendix C Installing the Server Into a Rack With Optional Slide Rails C-78. If available, extend the anti-tilt bar at the bottom of the rack. (See FI
C-8 Sun Fire X2250 Server Service Manual • April 20091. Push the slide rails into the slide-rail assemblies in the rack as far as possible.2. Raise th
Appendix C Installing the Server Into a Rack With Optional Slide Rails C-9Caution – Verify that the server is securely mounted in the rack and that th
C-10 Sun Fire X2250 Server Service Manual • April 2009FIGURE C-7 Inserting the CMA Rail Extension Into the Back of the Left Slide RailCMA railextensio
Appendix C Installing the Server Into a Rack With Optional Slide Rails C-114. Verify that the CMA rail extension engages the slide rail, as shown inFI
C-12 Sun Fire X2250 Server Service Manual • April 20095. Insert the CMA’s mounting bracket connector into the right slide rail until theconnector lock
Appendix C Installing the Server Into a Rack With Optional Slide Rails C-136. Insert the right CMA slide-rail connector into the right slide-rail asse
C-14 Sun Fire X2250 Server Service Manual • April 20097. Insert the left CMA slide-rail connector into the rail extension on the left slide-rail assem
Appendix C Installing the Server Into a Rack With Optional Slide Rails C-158. Position the cable hangers in the appropriate mounting holes in the CMA
1-1CHAPTER1Sun Fire X2250 Server OverviewThis chapter provides an overview of the Sun Fire X2250 server, as well as power-onand power-off procedures a
C-16 Sun Fire X2250 Server Service Manual • April 2009C.6 Verifying Operation of the Slide Railsand CMAUse this procedure to ensure that the slide rai
Index-1IndexAair ductlocation, 1-6, 4-5replacing, 4-20altitude specifications, A-3Bbatterylocation, 1-6, 4-5replacing, 4-33BIOS firmwareCD, 1-4updating
Index-2 Sun Fire X2250 Server Service Manual • February 2010diagnostics CD, 1-4DIMMs, see memory modulesdriver updates, -xidual blower modulereplacing
Index-3physical specifications, A-1postinstallation instructions, 4-3Power button, 1-5power connector, 1-5power LED, 1-5power problemstroubleshooting,
Index-4 Sun Fire X2250 Server Service Manual • February 2010Tools and Drivers CDdescription, 1-4tools for maintenance procedures, 4-1troubleshooting,
1-2 Sun Fire X2250 Server Service Manual • April 20091.1 FeaturesTABLE 1-1 lists the system’s key components.1.2 Operating System and SoftwareThis sec
Chapter 1 Sun Fire X2250 Server Overview 1-31.2.1 Preinstalled SoftwareIf you ordered a hard drive with your Sun Fire X2250 server, the hard drive mig
1-4 Sun Fire X2250 Server Service Manual • April 20091.2.3 Tools & Drivers CD SoftwareThe Sun Fire X2250 server Tools & Drivers CD, which is a
Chapter 1 Sun Fire X2250 Server Overview 1-5FIGURE 1-2 shows the back panel of the Sun Fire X2250 server.FIGURE 1-2 Back Panel1.3.2 Internal Component
1-6 Sun Fire X2250 Server Service Manual • April 2009FIGURE 1-3 Sun Fire X2250 Server System ComponentsTABLE 1-4 Sun Fire X2250 Server Internal Compon
Chapter 1 Sun Fire X2250 Server Overview 1-71.4 Powering On and Powering Off theServerYou only need to apply standby power to the server at this point
PleaseRecycleCopyright © 2010 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.Sun Microsystems,
1-8 Sun Fire X2250 Server Service Manual • April 20091.4.2 Powering On Main Power ModeTo power on main power for all server components:1. Verify that
Chapter 1 Sun Fire X2250 Server Overview 1-91.4.4 Clearing the CMOSYou can use this procedure to clear the server's CMOS settings in the case of
1-10 Sun Fire X2250 Server Service Manual • April 2009
2-1CHAPTER2TroubleshootingThis chapter contains information on troubleshooting procedures and technicalsupport contacts.The following sections are inc
2-2 Sun Fire X2250 Server Service Manual • April 20092.1 Troubleshooting OverviewBefore troubleshooting your specific server problem, answer the follo
Chapter 2 Troubleshooting 2-32.2.1 Performing an External Visual Inspection1. Turn off the system and any attached peripherals (if applicable).2. Veri
2-4 Sun Fire X2250 Server Service Manual • April 20092.3 Troubleshooting ProceduresTABLE 2-1 lists problems that might arise as you use your server. P
Chapter 2 Troubleshooting 2-5System cannot readthe hard diskinformation.Do the following:1. Turn off the server by pressing the Power button.2. Remove
2-6 Sun Fire X2250 Server Service Manual • April 2009No video is displayedon the monitorscreen.Check the following:• Is the monitor cable connected to
Chapter 2 Troubleshooting 2-72.4 Getting Technical AssistanceIf the troubleshooting procedures in this chapter fail to solve your problem, seeTABLE 2-
iiiContentsPreface ix1. Sun Fire X2250 Server Overview 1–11.1 Features 1–21.2 Operating System and Software 1–21.2.1 Preinstalled Software 1–31.2.2 Su
2-8 Sun Fire X2250 Server Service Manual • April 2009
3-1CHAPTER3Performing DiagnosticsThis chapter assists you with using the Diagnostics application on the Sun Fire X2250Server Tools & Drivers CD. T
3-2 Sun Fire X2250 Server Service Manual • April 20093.1 Pc-Check Diagnostics OverviewSun Fire X2250 server diagnostics are contained in the DOS-based
Chapter 3 Performing Diagnostics 3-3To run a specific hardware component test, select Advanced Diagnostics Test.Torunone of the test scripts supplied
3-4 Sun Fire X2250 Server Service Manual • April 20093.3 Advanced Diagnostics Tests MenuOptionsTABLE 3-2 gives the name and a brief description of eac
Chapter 3 Performing Diagnostics 3-5Diskettes Not applicable for the Sun Fire X2250 server.Hard Disks Details information about the hard disk, and inc
3-6 Sun Fire X2250 Server Service Manual • April 20093.3.1 Testing the Hard Disk1. From the main menu, choose Advanced Diagnostics Tests.2. From the A
Chapter 3 Performing Diagnostics 3-7 Device Test SettingsEnables you to select the test time durations of the devices and the test level. Number of
3-8 Sun Fire X2250 Server Service Manual • April 2009When you select the Immediate Burn-in Testing menu option, the ContinuousBurn-in Testing window i
Chapter 3 Performing Diagnostics 3-91. From the main menu, choose Immediate Burn-in Testing.The top portion of the window lists the options described
iv Sun Fire X2250 Server Service Manual • February 20102.1 Troubleshooting Overview 2–22.2 Performing Visual Inspections 2–22.2.1 Performing an Extern
3-10 Sun Fire X2250 Server Service Manual • April 20092. Complete one of the following options: Load Burn-in ScriptEnter one of the following: quick
Chapter 3 Performing Diagnostics 3-11 Section 3.6.3, “Creating a Log File on the Diagnostic Partition” on page 3-12 Section 3.6.4, “Accessing the Di
3-12 Sun Fire X2250 Server Service Manual • April 20099. Type Y to erase the data and the partition.10. Repeat Step 6 through Step 9 until all partiti
Chapter 3 Performing Diagnostics 3-13The following procedure shows an example of how to create and access a log file onthe diagnostic partition for th
3-14 Sun Fire X2250 Server Service Manual • April 20094. Determine if your diagnostic partition has been configured to be mounted bytyping the followi
Chapter 3 Performing Diagnostics 3-153.6.5 Accessing the Diagnostic Partition on theSolaris 10 Operating SystemTo access the diagnostic partition on t
3-16 Sun Fire X2250 Server Service Manual • April 20093.6.6 Accessing the Diagnostic Partition on theWindows Server 2003 Operating SystemThe Windows 2
Chapter 3 Performing Diagnostics 3-17 MotherboardThis section shows the following tests conducted against the motherboard:DMA Controller Tests, Syste
3-18 Sun Fire X2250 Server Service Manual • April 20093.8 Print Results ReportThe Print Results Report option enables you to print system diagnostic r
4-1CHAPTER4Maintaining the Sun Fire X2250ServerThis chapter describes how to add, replace, and configure components in the SunFire X2250 server after
Contents v3.10 Exit to DOS 3–184. Maintaining the Sun Fire X2250 Server 4–14.1 Tools and Supplies Needed 4–14.2 Installation Precautions 4–24.2.1 ESD
4-2 Sun Fire X2250 Server Service Manual • April 2009 Alcohol pads (for CPU replacement by service personnel only) 5 mm nut driver (for motherboard
Chapter 4 Maintaining the Sun Fire X2250 Server 4-32. Remove the server cover.See Section 4.3, “Powering Off the Server and Removing the Cover” on pag
4-4 Sun Fire X2250 Server Service Manual • April 20094. Label and disconnect all peripheral cables and all telecommunication linesconnected to I/O con
Chapter 4 Maintaining the Sun Fire X2250 Server 4-54.4 Locations of Server ComponentsFIGURE 4-2 Sun Fire X2250 Server System ComponentsTABLE 4-1 Sun F
4-6 Sun Fire X2250 Server Service Manual • April 20094.5 Component Replacement ProceduresThe following components are customer-replaceable units (CRUs
Chapter 4 Maintaining the Sun Fire X2250 Server 4-74.5.1 Replacing the I/O BoardThe following procedures describe how to remove and replace an I/O boa
4-8 Sun Fire X2250 Server Service Manual • April 20094.5.1.2 Installing the I/O BoardTo install the I/O board:1. Position the I/O board on top of the
Chapter 4 Maintaining the Sun Fire X2250 Server 4-94.5.2 Replacing the PCIe Card and Riser AssemblyNote – Many of the illustrations in this section sh
4-10 Sun Fire X2250 Server Service Manual • April 2009Note – The examples shown in these procedures use the x8 card, but the installationand removal i
Chapter 4 Maintaining the Sun Fire X2250 Server 4-11FIGURE 4-7 Removing a PCIe Card4.5.2.2 Installing the PCIe Card and Riser Card AssemblyTo install
vi Sun Fire X2250 Server Service Manual • February 20104.5.7 Replacing the Power Supply 4–224.5.7.1 Removing the Power Supply 4–224.5.7.2 Installing t
4-12 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-9 Installing the PCIe Card3. Reinstall the riser assembly into the connector on the mot
Chapter 4 Maintaining the Sun Fire X2250 Server 4-134. Check the routing of all cables for obstructions, and then reinstall the cover asdescribed in S
4-14 Sun Fire X2250 Server Service Manual • April 20093. Grasp the carrier bezel with both hands and carefully pull the carrier out of thedrive bay.No
Chapter 4 Maintaining the Sun Fire X2250 Server 4-154.5.4 Replacing an HDD Backplane AssemblyThe following procedure describes how to replace the hard
4-16 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-13 Removing the HDD Backplane Assembly4.5.4.2 Replacing an HDD BackplaneTo install the
Chapter 4 Maintaining the Sun Fire X2250 Server 4-17FIGURE 4-14 Replacing the HDD Backplane Assembly5. Reinsert the HDD as described in Section 4.5.3.
4-18 Sun Fire X2250 Server Service Manual • April 20094.5.5 Removing and Installing the ODD DriveAssemblyThe following procedure describes how to repl
Chapter 4 Maintaining the Sun Fire X2250 Server 4-194. Pull the ODD drive out the front of the chassis.Caution – Move the assembly by grasping it by i
4-20 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-17 Installing the ODD Assembly4. Reinstall the ODD drive cable.5. Check the routing of
Chapter 4 Maintaining the Sun Fire X2250 Server 4-21FIGURE 4-18 Removing the Air Duct4.5.6.2 Installing the Air DuctTo install the air duct:1. Positio
Contents viiA.4 Serial Connector Pin Assignments A–4B. Using the Tools & Drivers CD B–1B.1 Tools & Drivers CD Contents B–1B.2 Updating BIOS B–
4-22 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-19 Installing the Air Duct4.5.7 Replacing the Power SupplyThe following procedures desc
Chapter 4 Maintaining the Sun Fire X2250 Server 4-23FIGURE 4-20 Removing the Power Supply6. Lift the power supply out of the chassis.4.5.7.2 Installin
4-24 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-21 Installing the Power Supply4. Connect three of the power supply cables to the mother
Chapter 4 Maintaining the Sun Fire X2250 Server 4-257. Replace the air duct. See Section 4.5.6.2, “Installing the Air Duct” on page 4-21.8. Check the
4-26 Sun Fire X2250 Server Service Manual • April 20094.5.8.2 Installing the Fan ModuleTo install the system fan module:1. Position the fan so that th
Chapter 4 Maintaining the Sun Fire X2250 Server 4-271. Power off the system and remove the cover as described in Section 4.3,“Powering Off the Server
4-28 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-25 Installing the Dual Blower Module2. Gently push the blower module down, until you he
Chapter 4 Maintaining the Sun Fire X2250 Server 4-29 DIMM pairs must be populated in the following DIMM slot order: A0 & B0, C0 &D0, A1 &
4-30 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-27 Bank 1 DIMM Slot Locations3. Remove a DIMM by pressing down on the ejector levers at
Chapter 4 Maintaining the Sun Fire X2250 Server 4-31FIGURE 4-28 Removing a DIMM4.5.10.3 Installing a DIMMTo install a DIMM:1. Refer to Section 4.5.10.
viii Sun Fire X2250 Server Service Manual • February 2010Index Index–1
4-32 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-29 Installing a DIMM4. Using both thumbs, press the DIMM straight down into the DIMM sl
Chapter 4 Maintaining the Sun Fire X2250 Server 4-334.5.11 Replacing the System BatteryThe system battery is a common CR2032 calculator battery.You mi
4-34 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-30 Removing the System BatteryCaution – Do not dispose of the battery with regular wast
Chapter 4 Maintaining the Sun Fire X2250 Server 4-354.5.11.2 Installing the System BatteryTo install the system battery:1. Insert the new system batte
4-36 Sun Fire X2250 Server Service Manual • April 20094.5.12 Replacing a CPU and HeatsinkThe following procedure describes how to replace a CPU. The S
Chapter 4 Maintaining the Sun Fire X2250 Server 4-37FIGURE 4-32 Removing a HeatsinkCaution – The heatsink can become extremely hot. Be sure it has had
4-38 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-33 Removing the CPU8. Lift the CPU out of the socket, leaving the release lever in the
Chapter 4 Maintaining the Sun Fire X2250 Server 4-393. Align the small triangle, on the upper left corner of the CPU, with the triangleon the corner o
4-40 Sun Fire X2250 Server Service Manual • April 20097. Use the entire syringe contents to apply thermal grease in a circular pattern tothe top of th
Chapter 4 Maintaining the Sun Fire X2250 Server 4-41FIGURE 4-35 Installing the Heatsink13. Reinstall the cover.4.5.13 Installing a New CPUNote – Repla
ixPrefaceThe Sun Fire X2250 Server Service Manual provides a detailed description of thehardware and software applications that support the Sun Fire™
4-42 Sun Fire X2250 Server Service Manual • April 20093. Ensure that the socket release lever is in the fully open, perpendicular positionand the CPU
Chapter 4 Maintaining the Sun Fire X2250 Server 4-437. Rotate the socket release lever down until it snaps into place, securing the CPUin the socket.8
4-44 Sun Fire X2250 Server Service Manual • April 20094.5.14 Replacing CablesFIGURE 4-38 shows the routing of the cables and motherboard connector loc
Chapter 4 Maintaining the Sun Fire X2250 Server 4-45TABLE 4-3 describes the motherboard cable connections.4.5.15 MotherboardThe following procedures d
4-46 Sun Fire X2250 Server Service Manual • April 20096. Using a 5-mm nut driver, remove the screws attaching the serial connector to thechassis.FIGUR
Chapter 4 Maintaining the Sun Fire X2250 Server 4-471. Center the motherboard on the chassis so that the screw holes in themotherboard align with the
4-48 Sun Fire X2250 Server Service Manual • April 20096. Reconnect all internal system cables.See Section 4.5.14, “Replacing Cables” on page 4-45.7. R
Chapter 4 Maintaining the Sun Fire X2250 Server 4-49
4-50 Sun Fire X2250 Server Service Manual • April 2009
A-1APPENDIXASystem SpecificationsThis Appendix contains the following specifications for the Sun Fire X2250 server. Section A.1, “Physical Specificat