3-6 Sun StorEdge A3500/A3500FC Hardware Configuration Guide December 1999
3.1.2.2 Module ID Switch
Ensure that the module IDs for the StorEdge D1000 disk arrays are set according to
TABLE 3-2.
3.1.2.3 SCSI Jumper Cables and Terminators
All Sun StorEdge D1000 disk arrays in this configuration should have SCSI jumper
cables between the middle SCSI connectors (IN/OUT-1 and IN/OUT-2) and a
differential SCSI terminator in the far right SCSI connector (IN/OUT-2). This
configuration is shown in
FIGURE 3-15.
TABLE 3-2 1x5 Module ID Switch Settings
Disk Array Number Module ID Setting
5 (Top) 5
44
33
22
1 (Bottom) 1