Strona 1 - User’s Guide

Sun Microsystems, Inc.www.sun.comSubmit comments about this document at: http://www.sun.com/hwdocs/feedbackSun Netra™CP3000 AdvancedMezzanine Card PCI

Strona 2

x Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010

Strona 3 - Contents

1-1CHAPTER1Getting StartedThis chapter provides information and procedures needed to install and make theSun Netra CP3000 AMC.1-HDD SAS disk operation

Strona 4

1-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20101.1 System RequirementsThe following sections

Strona 5 - Contents v

Chapter 1 Getting Started 1-31.1.4 Electrical and EnvironmentalSee Appendix B for electrical and environmental requirements.Caution – None of the inte

Strona 6

1-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20101.3 Handling AMCsCaution – The system is sens

Strona 7 - Typographic Conventions

Chapter 1 Getting Started 1-5 Do not use an oscilloscope probe on the components. The soldered pins are easilydamaged or shorted by the probe point.

Strona 8 - Third-Party Web Sites

1-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20101.5 AMC LEDsThe following tables give status

Strona 9 - Sun Welcomes Your Comments

Chapter 1 Getting Started 1-7Note – An AMC should be hot-swapped only when the LED is solid blue.TABLE 1-2 Hot-Swap BLUE LED StatesOrder Visible State

Strona 10

1-8 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20101.6 Removing and Installing AMCsThis section

Strona 11 - Getting Started

Chapter 1 Getting Started 1-9Note – Depending on how the Shelf controls deactivation, the Shelf might notinitiate deactivation when you disengage the

Strona 12 - 1.1 System Requirements

PleaseRecycleCopyright © 2010 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.Sun Microsystems,

Strona 13 - 1.2 Unpacking

1-10 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010FIGURE 1-2 Deactivating the AMCFigure Leg en

Strona 14 - 1.3 Handling AMCs

Chapter 1 Getting Started 1-117. Remove the AMC.FIGURE 1-3 Removing the AMC8. Replace the AMC with another AMC (FIGURE 1-7) or install a filler panel.

Strona 15 - 1.4 AMC Faceplate

1-12 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010Caution – Failure to fill all slots with AMC

Strona 16 - 1.5 AMC LEDs

Chapter 1 Getting Started 1-13Note – Depending on how the Shelf controls deactivation, the Shelf might notinitiate deactivation when you disengage the

Strona 17 - Hot-Swap BLUE LED States

1-14 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20103. Obtain the AMC card from the ship kit.Not

Strona 18 - 1.6.1 Removing an AMC

Chapter 1 Getting Started 1-15FIGURE 1-6 Opening the Injector/Ejector LatchFigure Leg end1 Fully In (IN) When IN, the module communicates to the shelf

Strona 19 - FIGURE 1-2)

1-16 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20106. Carefully align the edges of the AMC with

Strona 20 - Deactivating the AMC

Chapter 1 Getting Started 1-17FIGURE 1-7 Inserting the AMC Into a Blade Server8. Push the ejector latch in fully.If system power is on and AMC is inst

Strona 21 - 7. Remove the AMC

1-18 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010Caution – Failure to fill all slots with AMC

Strona 22 - FIGURE 1-4)

Chapter 1 Getting Started 1-19Note – This utility has many other uses and adjustable values. Parameteradjustments are permanently committed to flash m

Strona 23 - 1.6.3 Installing an AMC

iiiContentsPreface vii1. Getting Started 1–11.1 System Requirements 1–21.1.1 Operating Systems Compatibility 1–21.1.2 Chassis Compatibility 1–21.1.3 B

Strona 24 - Sample Top View

1-20 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010

Strona 25 - Figure Leg end

2-1CHAPTER2OverviewThis chapter introduces the key features of the AMC. This chapter includes aproduct definition, a list of product features, and fun

Strona 26

2-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20102.1 FeaturesPart of Sun’s ATCA platform, the

Strona 27

Chapter 2 Overview 2-3 Support for SATA, as defined in the Serial ATA Specification, version 1.0a.2.2 Key ComponentsThe following figure and sections

Strona 28 - Controller)

2-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20102.2.3 SAS ControllerThe AMC.1-HDD SAS disk in

Strona 29

Chapter 2 Overview 2-5 e-Keying as described in the AMC.0 specification FRU information LED indicators for hot-swap and OOS (out of service)2.2.6 P

Strona 30

2-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010Figure Leg endIndicator Color State Descripti

Strona 31 - Overview

Chapter 2 Overview 2-72.4 Functional DiagramFIGURE 2-3 AMC SAS-HDD Functional Block Diagram2.5 Technical Support and WarrantyIf you have any technical

Strona 32 - 2.1 Features

2-8 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010When you call Sun Services, indicate if the S

Strona 33 - 2.2 Key Components

Chapter 2 Overview 2-9FIGURE 2-4 Sun Netra CP3000 AMC.1-HDD SAS disk Barcode LabelingFigure Leg end1Final Assembly Number:• Assembly process label, wh

Strona 34 - 2.2.4 Flash

iv Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20101.7 Enabling and Disabling SAS Ports 1–18▼ To

Strona 35 - 2.3 Faceplate and LEDs

2-10 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20102.7 DisposalThe AMC might contain materials

Strona 36

3-1CHAPTER3Managing the AMCThis chapter describes the AMC management software.The Sun Netra CP3000 AMC.1-HDD SAS disk includes an IPMI-based ModuleMan

Strona 37 - 2.4 Functional Diagram

3-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20103.1 Monitoring and Control FunctionsThe MMC i

Strona 38 - FIGURE 2-4). The Sun barcode

Chapter 3 Managing the AMC 3-3Get Device SDR 29.3 S/E 21h MandatoryReserve Device SDRRepository29.4 S/E 22h MandatoryGet Sensor Reading Factors 29.5 S

Strona 39 - Chapter 2 Overview 2-9

3-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20103.3 FRU InformationBoard information such as

Strona 40 - 2.7 Disposal

Chapter 3 Managing the AMC 3-53.4 SensorsThe AMC.1-HDD SAS disk module management is connected to sensors monitoringkey board voltages and temperature

Strona 41 - Managing the AMC

3-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20103.5 Firmware and Software UpgradesFor up-to-d

Strona 42 - 3.2 IPMI Controller

4-1CHAPTER4Configuring the AMCThis chapter describes how to configure the AMC using the SAS Boot BIOSConfiguration Utility, the OpenBoot™ BIOS, and th

Strona 43 - AMC® Commands

4-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20104.1 Configuration ToolsThe configuration tool

Strona 44 - 3.3 FRU Information

Chapter 4 Configuring the AMC 4-34.2.1 Features and ConfigurationsThe Boot BIOS supports the following: Using multiple AMC.1 SAS modules Applying gl

Strona 45 - 3.4 Sensors

Contents v4. Configuring the AMC 4–14.1 Configuration Tools 4–24.2 Boot BIOS Utility 4–24.2.1 Features and Configurations 4–34.2.2 Launching the Boot

Strona 46 - Product Notes (820-7174)

4-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010FIGURE 4-1 Boot BIOS Main MenuThe menu displa

Strona 47 - Configuring the AMC

Chapter 4 Configuring the AMC 4-5FIGURE 4-2 Adapter Properties Menu5. Using the arrow keys, select the item of interest.6. Press ENTER to display the

Strona 48 - 4.2 Boot BIOS Utility

4-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20104.4 Extensible Firmware Interface (EFI)BIOSTh

Strona 49

A-1APPENDIXAConnectors and PortsThis appendix describes the connectors and ports you can use to communicate withthe host board and application-specifi

Strona 50

A-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010A.1 Connector Locations and AssignmentsThis m

Strona 51 - 4.3 OpenBoot BIOS

Appendix A Connectors and Ports A-39 12V 54 'PCIe_RX1_N' 99 No Connect 144 No Connect10 GND 55 GND 100 No Connect 145 No Connect11 No Connec

Strona 52

A-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010A.3 SAS Controller PortsThe AMC.1-HDD SAS dis

Strona 53 - Connectors and Ports

Appendix A Connectors and Ports A-5A.4 e-Keying PortsThe AMC.1-HDD SAS disk connects up to two SAS ports on the AMC connector.These ports are defined

Strona 54 - A.2 Connector Pinouts

A-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010

Strona 55 - Pin Assignments (Continued)

B-1APPENDIXBEnvironment SpecificationsThis appendix describes the electrical, environmental, and mechanical specifications.It includes illustrations o

Strona 56 - A.3 SAS Controller Ports

vi Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010C.4.1 EN 55022 Emissions C–4C.4.2 EN 55024 Imm

Strona 57 - A.4 e-Keying Ports

B-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010B.1 Electrical and EnvironmentalThe following

Strona 58

Appendix B Environment Specifications B-3Vibration Operating 1 G (20 to 300 Hz)Nonoperating 5 G (20 to 300 Hz)Shock Operating 100 G/1ms durationNonope

Strona 59 - Environment Specifications

B-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010B.1.3 Absolute Maximum RatingsThe following v

Strona 60 - B.1.2 Environmental

Appendix B Environment Specifications B-5B.3 MechanicalThis section includes the mechanical specifications for dimensions and weight. TheAMC.1-HDD SAS

Strona 61 - MTBF Values by Temperature

B-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010

Strona 62 - B.2 Reliability

C-1APPENDIXCAgency CertificationsThis appendix lists standards agencies and the certifications related to the Sun NetraCP3000 AMC.1-HDD SAS disk.This

Strona 63 - B.3 Mechanical

C-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010C.1 CE CertificationThe Sun Netra CP3000 AMC.

Strona 64

Appendix C Agency Certifications C-3C.3 Safety UL/cUL 60950--1 Safety for Information Technology Equipment (UL File#E138926) EN/IEC 60950-1:2001, 1S

Strona 65 - Agency Certifications

C-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010C.4 Emissions Test Regulations FCC Part 15,

Strona 66 - C.2 NEBS/ETSI

Appendix C Agency Certifications C-5C.5 Regulatory InformationCaution – If you make any modification to the AMC not expressly approved bySun, you coul

Strona 67 - C.3 Safety

viiPrefaceThe Netra™ CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS ControllerUser’s Guide describes the installation and configuration of the

Strona 68 - C.4.2 EN 55024 Immunity

C-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 20101. Ce dispositif peut ne pas causer l'in

Strona 69 - C.5 Regulatory Information

Index-1IndexNumerics10GbE local PHY, 3-2Aabsolute maximum ratings, B-4AMC flexing, preventing, 1-4antistatic bag, 1-3Bboard status, 1-6board voltages,

Strona 70

Index-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • MarchMMAC addresslabel, 2-8management voltage, B-4m

Strona 71

viii Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010Related DocumentationThe following table lis

Strona 72

Preface ixSun Welcomes Your CommentsSun is interested in improving its documentation and welcomes your comments andsuggestions. You can submit your co

Komentarze do niniejszej Instrukcji

Brak uwag