Sun Microsystems, Inc.
www.sun.com
Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun StorEdge™ PCI/PCI-X Dual
Ultra320 SCSI Host Adapter
Installation Guide
Part No. 817-5827-13
January 2007, Revision A
Przeglądanie stron 0
1 2 3 4 5 6 ... 47 48

Podsumowanie treści

Strona 1 - Installation Guide

Sun Microsystems, Inc.www.sun.comSubmit comments about this document at: http://www.sun.com/hwdocs/feedbackSun StorEdge™ PCI/PCI-X DualUltra320 SCSI H

Strona 2

x Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007

Strona 3 - Contents

1CHAPTER1Installing, Connecting, and Testingthe Host AdapterThis chapter describes the Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI host adapterand expla

Strona 4

2 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007FeaturesThe Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI host a

Strona 5 - Before You Read This Book

Chapter 1 Installing, Connecting, and Testing the Host Adapter 3 512K bytes of Flash ROM for booting in a Sun SPARC or a Sun Solaris x86 OSprocessor-

Strona 6 - Using UNIX Commands

4 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007▼ To Prepare for Hardware Installation1. Read and observe th

Strona 7 - Related Documentation

Chapter 1 Installing, Connecting, and Testing the Host Adapter 5Caution – Do not disconnect the power cord from the system or from the walloutlet. Thi

Strona 8 - Accessing Sun Documentation

6 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 20079. Unpack the host adapter.You should have the following ite

Strona 9 - Sun Welcomes Your Comments

Chapter 1 Installing, Connecting, and Testing the Host Adapter 7▼ To Install the Host Adapter1. Open the system.Refer to your system documentation for

Strona 10

8 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007Connecting the Host AdapterBefore you connect the host adapt

Strona 11 - ■ “Features” on page 2

Chapter 1 Installing, Connecting, and Testing the Host Adapter 9Testing the Host AdapterYou should test the host adapter installation using the probe-

Strona 12 - Features

PleaseRecycleCopyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.Sun Microsystems, I

Strona 13 - Installing the Host Adapter

10 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007▼ To Test the Installation With the SunVTSSoftwareUse the t

Strona 14 - # shutdown

Chapter 1 Installing, Connecting, and Testing the Host Adapter 11Booting the Host AdapterThe Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI host adapter us

Strona 15

12 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007

Strona 16 - ■ Antistatic wrist strap

13APPENDIXAUltra320 SCSI ConfigurationThis appendix provides general information about Ultra320 SCSI configurationrules. The following topics are disc

Strona 17 - To Install the Host Adapter

14 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007Bus LengthThe maximum SCSI bus length is determined by the

Strona 18 - Connecting the Host Adapter

Appendix A Ultra320 SCSI Configuration 15Cabling and TerminationUse the following cabling guidelines to ensure proper device cabling andtermination.Ca

Strona 19 - Testing the Host Adapter

16 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007SCSI SymbolsOne of the four following symbols is placed ne

Strona 20 - Software

17APPENDIXBSpecificationsThe chapter contains the specifications for the low-voltage differential (LVD) SunStorEdge PCI/PCI-X Dual Ultra320 SCSI host

Strona 21 - Booting the Host Adapter

18 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007Power RequirementsPerformance SpecificationsTABLE B-2 Powe

Strona 22

Appendix B Specifications 19PCI Edge Connector Pin DefinitionsTABLE B-4 PCI Edge Connector Pin Definitions J1B (Top)Pin Description Pin Description Pi

Strona 23 - Ultra320 SCSI Configuration

iiiContentsPreface v1. Installing, Connecting, and Testing the Host Adapter 1Features 2Installing the Host Adapter 3▼ To Prepare for Hardware Installa

Strona 24 - Bus Length

20 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007TABLE B-5 PCI Edge Connector Pin Definitions J1A (Bottom)P

Strona 25 - Cabling and Termination

Appendix B Specifications 21SCSI Connector Pin DefinitionsFIGURE B-1 VHDCI and Internal SCSI ConnectorsTABLE B-6 SCSI Connector Pin DefinitionsPin Des

Strona 26 - SCSI Symbols

22 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 200718 TERMPWR 41 SD(0)- 64 GND19 OPEN 42 SD(1)- 65 SD(8)-20 +

Strona 27 - Specifications

23APPENDIXCDeclaration of Conformity,Regulatory Compliance, and SafetyStatementsThis appendix contains the following information that applies to the S

Strona 28 - Performance Specifications

24 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007Declaration of ConformityEMCUSA - FCC Class BThis equipmen

Strona 29 - Appendix B Specifications 19

Appendix C Declaration of Conformity 25

Strona 30

26 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007Regulatory Compliance StatementsYour Sun product is marked

Strona 31 - Appendix B Specifications 21

Appendix C Declaration of Conformity, Regulatory, and Safety Information 27Safety Agency ComplianceStatementsRead this section before beginning any p

Strona 32

28 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007SELV ComplianceSafety status of I/O connections comply to S

Strona 33 - Statements

Appendix C Declaration of Conformity, Regulatory, and Safety Information 29Rack System WarningThe following warnings apply to Racks and Rack Mounteds

Strona 34

iv Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007SCSI Symbols 16B. Specifications 17Physical Dimensions 17Po

Strona 35

30 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007Attention – Tensions dangereuses. Pourréduire les risques d

Strona 36 - FCC Class B Notice

Appendix C Declaration of Conformity, Regulatory, and Safety Information 31Mise en garde relative aux batteriesAttention – Les batteries risquentd’ex

Strona 37 - Safety Agency Compliance

32 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007Einhaltung sicherheitsbehördlicherVorschriftenLesen Sie vor

Strona 38 - System Unit Cover

Appendix C Declaration of Conformity, Regulatory, and Safety Information 33Anschluss des NetzkabelsAchtung – Sun-Geräte sind fürStromversorgungssyste

Strona 39 - Symboles

34 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007Position im Rack eingebaut werden, gefolgtvon den Systemen,

Strona 40 - Conformité SELV

Appendix C Declaration of Conformity, Regulatory, and Safety Information 35En función del tipo de interruptor de alimentación del quedisponga el disp

Strona 41 - Périphériques CD et DVD

36 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007La siguiente medida solamente se aplica a aquellosdispositi

Strona 42 - Vorschriften

Appendix C Declaration of Conformity, Regulatory, and Safety Information 37Dispositivos de CD y DVDLa siguiente medida se aplica a los dispositivos d

Strona 43 - Gehäuseabdeckung

38 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007

Strona 44 - Normativas de seguridad

vPrefaceThis Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide isintended for experienced system administrators.Before You Rea

Strona 45

vi Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007How This Book Is Organized Chapter 1 describes the Sun Sto

Strona 46 - Laser Klasse 1

Preface viiTypographic ConventionsRelated DocumentationTypeface** The settings on your browser might differ from these settings.Meaning ExamplesAaBbCc

Strona 47 - Dispositivos de CD y DVD

viii Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007Accessing Sun DocumentationYou can view, print, or purcha

Strona 48

Preface ixThird-Party Web SitesSun is not responsible for the availability of third-party web sites mentioned in thisdocument. Sun does not endorse an